{"id":7561,"date":"2026-11-19T17:45:54","date_gmt":"2026-11-19T09:45:54","guid":{"rendered":"https:\/\/www.metal-domes.com\/blog\/?p=7561"},"modified":"2026-11-20T10:09:28","modified_gmt":"2026-11-20T02:09:28","slug":"metal-dome-free-height","status":"publish","type":"post","link":"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/","title":{"rendered":"Metal Dome Free Height: Measurement, Tolerance and Installed Stack"},"content":{"rendered":"<div class=\"yzp-no-index\"><\/div><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_69_1 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<div class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/div>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#What_Is_Metal_Dome_Free_Height\" title=\"What Is Metal Dome Free Height?\">What Is Metal Dome Free Height?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#Where_Is_the_Height_Datum_on_a_Loose_Dome\" title=\"Where Is the Height Datum on a Loose Dome?\">Where Is the Height Datum on a Loose Dome?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#How_Do_You_Measure_Snap_Dome_Free_Height\" title=\"How Do You Measure Snap Dome Free Height?\">How Do You Measure Snap Dome Free Height?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#Does_Preconditioning_Change_the_Reading\" title=\"Does Preconditioning Change the Reading?\">Does Preconditioning Change the Reading?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#Free_Height_vs_Travel_and_Metal_Thickness\" title=\"Free Height vs Travel and Metal Thickness\">Free Height vs Travel and Metal Thickness<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#How_Is_Metal_Dome_Height_Tolerance_Specified\" title=\"How Is Metal Dome Height Tolerance Specified?\">How Is Metal Dome Height Tolerance Specified?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#How_Does_Installed_Dome_Height_Differ\" title=\"How Does Installed Dome Height Differ?\">How Does Installed Dome Height Differ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#How_Do_You_Build_a_Switch_Height_Stack\" title=\"How Do You Build a Switch Height Stack?\">How Do You Build a Switch Height Stack?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#What_Causes_Height_Readings_to_Disagree\" title=\"What Causes Height Readings to Disagree?\">What Causes Height Readings to Disagree?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#How_Should_Height_Be_Checked_in_an_Assembly\" title=\"How Should Height Be Checked in an Assembly?\">How Should Height Be Checked in an Assembly?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#Which_Dome_Format_Fits_the_Height_Constraint\" title=\"Which Dome Format Fits the Height Constraint?\">Which Dome Format Fits the Height Constraint?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/#Metal_Dome_Free_Height_FAQs\" title=\"Metal Dome Free Height FAQs\">Metal Dome Free Height FAQs<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n\n<p><strong><a href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/\">Metal dome free height<\/a><\/strong> is the distance from the resting support plane to the highest point of an unloaded snap dome. It is a loose-part dimension, not the button height after adhesive, PCB pads and an enclosure have been assembled. A useful specification therefore identifies the datum, the dome state, the measurement method and the allowable range. Without those conditions, two height readings can disagree even when neither operator made an error.<\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7568\" src=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-hero-v2.jpg\" alt=\"Real four-leg metal dome shapes with the full article title on a light overlay\" width=\"600\" height=\"400\" srcset=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-hero-v2.jpg 600w, https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-hero-v2-300x200.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Is_Metal_Dome_Free_Height\"><\/span>What Is Metal Dome Free Height?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Free height is the vertical distance from the dome&#8217;s support surface to its unpressed apex. The supports may be discrete feet on a four-leg dome or a continuous rim on a round dome. The part rests in its normal orientation, with no actuator or gauge load flattening its crown.<\/p>\n\n\n<p>The dimension matters because it sets part of the available clearance under a button and influences where the actuator first touches the dome. It does not, by itself, predict trip force, electrical make point or tactile life. Those are separate properties that need a part-specific drawing or force-displacement test.<\/p>\n\n\n<p>Record whether the measured part is a loose component or a dome held by a carrier. Adhesive tension, a spacer and the PCB support can shift an assembly reading, even though the original loose dome had the specified free height.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Where_Is_the_Height_Datum_on_a_Loose_Dome\"><\/span>Where Is the Height Datum on a Loose Dome?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>The datum is the flat surface on which the intended supports rest. For a four-leg part, all usable feet should seat without rocking; for a round part, the rim defines the contact plane. Measure from that plane to the crown apex, not from the underside of a tilted loose part or from a nearby feature that is not a support.<\/p>\n\n\n<p>If one foot is bent, a tabletop reading can depend on orientation and may conceal a coplanarity problem. Check seating first. Do not push a rocking dome flat merely to obtain a convenient height number, because the force used to seat it changes the state being measured.<\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7573\" src=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-loose-shapes-v3.jpg\" alt=\"Real loose metal domes in four-leg and round forms, with different support feet and rims\" width=\"600\" height=\"379\" srcset=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-loose-shapes-v3.jpg 600w, https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-loose-shapes-v3-300x190.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Do_You_Measure_Snap_Dome_Free_Height\"><\/span>How Do You Measure Snap Dome Free Height?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>For a repeatable snap dome free height measurement, use a clean, flat reference surface and a non-contact optical height system or a probe with a documented force low enough not to deflect the crown. Zero the instrument on the support plane, then read the highest point of the resting dome. A probe can be suitable, but its tip and contact force must be part of the method.<\/p>\n\n\n<p>Document the part orientation, equipment resolution, support fixture and whether the value is an individual reading or a sampled distribution. Check at least a few samples from the same lot at the intended conditioning state, then compare the measured range with the drawing. A single favorable reading cannot establish lot capability.<\/p>\n\n\n<p>When an optical system finds a different apex than a contact gauge, check whether the contact tip is landing on a dimple, touching a sloped area or compressing the crown. Re-run both methods on the same marked sample before treating the discrepancy as a production drift.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Does_Preconditioning_Change_the_Reading\"><\/span>Does Preconditioning Change the Reading?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>It can. Initial actuations may relax forming stress or settle a dome in a way that changes the measured free height. One published manufacturer inspection method measures height after ten actuations, but that is a supplier-specific procedure, not a universal requirement for every metal dome.<\/p>\n\n\n<p>For incoming inspection, state whether the drawing limit applies before or after cycling. If the supplier&#8217;s drawing uses a preconditioned value but the buyer tests an as-received part, the results are not directly comparable. Agree on the actuation fixture and cycle count before investigating a supposed out-of-tolerance lot.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Free_Height_vs_Travel_and_Metal_Thickness\"><\/span>Free Height vs Travel and Metal Thickness<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Free height, travel and material thickness are different dimensions. Free height describes the resting apex above the support plane. Travel is movement through a defined actuation event or to a specified contact plane. Thickness describes the sheet metal itself. A dimple can also change the contact geometry without making the entire dome taller by the same amount.<\/p>\n\n\n<p>Do not subtract a catalog travel value from a free-height value and assume the result is the assembled switch gap. Catalog travel may use a different contact reference, while the PCB&#8217;s center pad and support pads may not be level. The useful comparison is a measured force-displacement trace with the actual contact make point identified.<\/p>\n\n\n<figure class=\"wp-block-table\" style=\"overflow-x:auto\"><table class=\"has-fixed-layout\" style=\"min-width:600px\"><thead><tr><th>Quantity<\/th><th>Reference<\/th><th>What it answers<\/th><\/tr><\/thead><tbody><tr><td>Free height<\/td><td>Loose support plane to unloaded apex<\/td><td>How tall the loose dome stands<\/td><\/tr><tr><td>Installed dome height<\/td><td>Declared PCB or pad datum to installed apex<\/td><td>Where the dome sits in the product stack<\/td><\/tr><tr><td>Travel<\/td><td>Declared start and end positions during actuation<\/td><td>How far the dome moves to the specified event<\/td><\/tr><tr><td>Metal thickness<\/td><td>Sheet cross-section<\/td><td>Material dimension, not dome rise<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Is_Metal_Dome_Height_Tolerance_Specified\"><\/span>How Is Metal Dome Height Tolerance Specified?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Metal dome height tolerance belongs on the released part drawing as a nominal value with an allowable interval or upper and lower limits, together with a measurement method. There is no defensible universal tolerance to apply to every diameter, shape and force grade. The acceptable range depends on the exact tooling, the forming process, the inspection state and the switch stack that consumes the height variation.<\/p>\n\n\n<p>For example, a drawing can require an unloaded apex measurement from the seated-foot plane after a stated conditioning sequence; it should then specify the actual acceptance limits in millimeters. That is a drawing-format example, not an implied manufacturing capability or a suggested default limit. If the customer&#8217;s button gap is tight, ask for measured sample distributions and a stack analysis before tightening the loose-part limit.<\/p>\n\n\n<p>A tolerance on dome height does not replace a tolerance on support-foot flatness, pad thickness or carrier placement. These dimensions can move the installed apex independently. Keep the part limit and the assembly limit separate so an out-of-spec assembly can be traced to the correct contributor.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Does_Installed_Dome_Height_Differ\"><\/span>How Does Installed Dome Height Differ?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Installed dome height is measured in the actual switch assembly from a declared datum, such as the PCB top surface or the top of a support pad, to the resting apex. It may differ from the loose-part free height because the feet sit on plated pads, the dome is positioned by adhesive or a carrier, and film tension may create preload.<\/p>\n\n\n<p>Always identify the datum in an installed measurement. A reading from the PCB laminate top is not interchangeable with one from the raised gold support pad. If the adhesive film crosses the dome apex, also state whether the measured top is the metal crown or the film surface.<\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7570\" src=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-installed-photo-v2.jpg\" alt=\"Real round metal domes installed over contact pads on a green PCB; installed height depends on the assembly datum\" width=\"600\" height=\"480\" srcset=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-installed-photo-v2.jpg 600w, https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-installed-photo-v2-300x240.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Do_You_Build_a_Switch_Height_Stack\"><\/span>How Do You Build a Switch Height Stack?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Start with one fixed assembly datum, then list every dimension between it and the underside of the actuator at rest. Include support pad height, the installed dome apex, retaining film where it crosses the load path, spacer and overlay geometry, and the housing or button stop. Use the actual drawing tolerances for each element; do not combine unrelated nominal values into an invented allowance.<\/p>\n\n\n<p>Calculate the smallest and largest possible actuator-to-dome gap from the relevant extremes. At the smallest gap, check for unwanted preload and a closed or weakened switch. At the largest gap, check whether the available button stroke still reaches a reliable electrical make point without excessive overtravel. Then test built assemblies at those boundary conditions.<\/p>\n\n\n<figure class=\"wp-block-table\" style=\"overflow-x:auto\"><table class=\"has-fixed-layout\" style=\"min-width:600px\"><thead><tr><th>Stack input<\/th><th>Evidence to use<\/th><th>Failure if overlooked<\/th><\/tr><\/thead><tbody><tr><td>Support-pad elevation<\/td><td>PCB fabrication drawing or measured build<\/td><td>Wrong installed datum<\/td><\/tr><tr><td>Dome free height and seating<\/td><td>Part drawing and conditioned sample readings<\/td><td>Preload or excess gap<\/td><\/tr><tr><td>Carrier film and adhesive<\/td><td>Film stack drawing and assembled sample<\/td><td>Unplanned crown loading<\/td><\/tr><tr><td>Actuator rest and stop positions<\/td><td>Enclosure drawing and worst-case assembly<\/td><td>Missed actuation or damaging overtravel<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p>This is a tolerance-budget method, not a promise that every extreme occurs simultaneously in production. Use worst-case arithmetic when a guaranteed clearance is required; a statistical stack needs enough process data and an explicitly accepted risk level. Prototype readings should include the complete force-displacement and make\/break response, not height alone.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Causes_Height_Readings_to_Disagree\"><\/span>What Causes Height Readings to Disagree?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>The common causes are different datums, different conditioning states, a contact probe that deflects the crown, a bent support foot, or a dome that is held off the PCB by adhesive or trapped air. These are measurement and assembly variables, not proof that the metal forming is wrong.<\/p>\n\n\n<p>Separate them in order. Measure the same loose dome on the same hard flat surface; verify foot seating and instrument zero; repeat after the specified cycling; then install that marked dome and read from the declared PCB datum. A change only after installation points toward support, film or actuator conditions rather than the loose part.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Should_Height_Be_Checked_in_an_Assembly\"><\/span>How Should Height Be Checked in an Assembly?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>Check installed height with the production-intent PCB, contact finish, carrier and enclosure, at the same resting state that the product specification uses. Measure several positions and record both the height and whether the actuator is already applying force. A dome can satisfy the loose-part height limit while a tight overlay leaves it preloaded.<\/p>\n\n\n<p>Follow the height reading with an electrical and tactile check. Confirm open state at rest, contact closure during the press and reopening on release. Compare force-displacement curves between a passing and failing key if the geometry looks correct. Height is an input to function, not a substitute for a functional switch test.<\/p>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Which_Dome_Format_Fits_the_Height_Constraint\"><\/span>Which Dome Format Fits the Height Constraint?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p>The right format is the one whose actual part drawing and assembly stack meet the available gap and stroke. Our <a href=\"https:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">four-leg metal domes<\/a> use defined feet, so seating and foot coplanarity matter to the free-height datum. Our <a href=\"https:\/\/www.metal-domes.com\/product\/metal-dome-C-Series.htm\">round metal domes<\/a> use a continuous rim and need a footprint that supports that rim as specified.<\/p>\n\n\n<p>When placement and retention are part of the problem, our <a href=\"https:\/\/www.metal-domes.com\/product-dome-array.htm\">metal dome arrays<\/a> provide a carrier format, but the carrier also adds an assembly variable. Compare the loose dome dimension with the installed array height; do not assume the two are identical. At EBest Circuit(Best Technology), we can review the PCB pad drawing, actuator gap and stroke, preferred dome format, and target test condition with you before part selection.<\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7574\" src=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-four-leg-array-v3.jpg\" alt=\"Real four-leg dome array mounted on PCB contact positions as one installed format\" width=\"600\" height=\"400\" srcset=\"https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-four-leg-array-v3.jpg 600w, https:\/\/www.metal-domes.com\/blog\/wp-content\/uploads\/2026\/11\/metal-dome-free-height-four-leg-array-v3-300x200.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Metal_Dome_Free_Height_FAQs\"><\/span>Metal Dome Free Height FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<p><strong>Is free height measured while pressing the dome?<\/strong> No. It is measured with the dome resting without an applied actuation load. If a contact gauge is used, its measurement force must be low enough and specified so it does not flatten the crown.<\/p>\n\n\n<p><strong>Can I use the same height tolerance for every dome?<\/strong> No. Use the part-specific drawing and agreed conditioning and inspection method. Different support shapes and forming conditions make a universal tolerance unreliable.<\/p>\n\n\n<p><strong>Is installed height always greater than free height?<\/strong> No. Raised support pads may increase the reading from a PCB datum, while film preload can lower the metal apex. The answer depends on the datum and the assembled stack.<\/p>\n\n\n<p>A sound specification connects <strong><a href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/\">metal dome free height<\/a><\/strong> to a declared measurement state and then validates the complete switch. That is how a dimension on a loose part becomes a reliable button in the product.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Metal dome free height is an unloaded dimension, not installed switch height. This guide covers the datum, measurement method, tolerance and stack checks. <a href=\"https:\/\/www.metal-domes.com\/blog\/2026\/11\/19\/metal-dome-free-height\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":57789,"featured_media":7568,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[100,3],"tags":[1489,1486,1487,1488],"class_list":["post-7561","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-metal-dome-assembly-2","category-metal-domes","tag-installed-dome-height","tag-metal-dome-free-height","tag-metal-dome-height-tolerance","tag-snap-dome-free-height-measurement"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/7561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/users\/57789"}],"replies":[{"embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/comments?post=7561"}],"version-history":[{"count":4,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/7561\/revisions"}],"predecessor-version":[{"id":7575,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/7561\/revisions\/7575"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/media\/7568"}],"wp:attachment":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/media?parent=7561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/categories?post=7561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/tags?post=7561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}