{"id":459,"date":"2015-03-24T18:06:54","date_gmt":"2015-03-24T10:06:54","guid":{"rendered":"http:\/\/www.metal-domes.com\/blog\/?p=459"},"modified":"2015-03-24T18:11:14","modified_gmt":"2015-03-24T10:11:14","slug":"why-metal-dome-array-doesnt-work-with-normal-force","status":"publish","type":"post","link":"https:\/\/www.metal-domes.com\/blog\/2015\/03\/24\/why-metal-dome-array-doesnt-work-with-normal-force\/","title":{"rendered":"Why metal dome array doesn\u2019t work with normal force?"},"content":{"rendered":"<div class=\"yzp-no-index\"><\/div><p>Recently we received a customer complaint, he said some <a title=\"metal dome array\" href=\"http:\/\/www.metal-domes.com\/product-dome-array.htm\">metal domes arrays<\/a> couldn&#8217;t work with required (normal) force and need higher push force, and even more some <a title=\"metal domes\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal domes<\/a> are locked and no response.<\/p>\n<p>The <a title=\"metal domes\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal domes<\/a>\u00a0customer uses is S6F-160-D-Ni, mean F-leg, diameter 6mm, force 160gf, with a dimple in center and nickel plated. The normal force is 160gf before assemble, but it seemed force changed a lot after assemble on PCB, and need higher force.<\/p>\n<p>Before seeing customer&#8217;s products,\u00a0we also couldn&#8217;t find the root reason, we checked and tested our <a title=\"metal domes\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal domes<\/a>\u00a0before assembly, it\u2019s no problem, but after saw customer\u2019s finished product, we understood why this issue happened, because customer\u2019s design housing design is not suitable with <a title=\"metal dome array\" href=\"http:\/\/www.metal-domes.com\/product-dome-array.htm\">metal domes array<\/a>.<\/p>\n<div style=\"width: 462px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.metal-domes.com\/blogimages\/2015\/metal-dome-array-force-assembly\/original-metal-dome-array-with-front-plate.jpg\" alt=\"customer's original metal dome array\" width=\"452\" height=\"147\" \/><p class=\"wp-caption-text\">customer&#8217;s original metal dome array<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Firstly, we checked\u00a0customer\u2019s assembled unit, obviously we found that <a title=\"four leg metal dome\" href=\"http:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">four legs of metal domes<\/a> are pressed and fixed by the front plate housing after assembly, so when people pressed the center of metal dome, the legs of <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">metal dome<\/a> can&#8217;t be extended peripherally as its original design, that means the front plate stop <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">metal dome<\/a>\u00a0becoming collapse, so you have to press metal dome use much higher force than the designed force (160gf for that metal dome) to force it become collapsed.<\/p>\n<div style=\"width: 438px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.metal-domes.com\/blogimages\/2015\/metal-dome-array-force-assembly\/original-metal-dome-array-with-front-plate-comments.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.metal-domes.com\/blogimages\/2015\/metal-dome-array-force-assembly\/original-metal-dome-array-with-front-plate-comments.jpg\" alt=\"metal dome with front plate\" width=\"428\" height=\"207\" \/><\/a><p class=\"wp-caption-text\">metal dome with front plate<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>But in most of cased, people don\u2019t know that and still press <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">metal dome<\/a>\u00a0use designed force (160gf) and then he will found out that <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/product\/metal-dome-F-Series.htm\">metal dome<\/a>\u00a0will not work. And then he have to increase the force, then bigger force damage <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\">metal dome<\/a> original structure, and then will change the force, and in most of case means reducing the clicking feeling. That&#8217;s also why we say metal dome can&#8217;t be soldered. (See more <a title=\"how metal dome works\" href=\"http:\/\/www.metal-domes.com\/blog\/2006\/11\/13\/how-metal-dome-works\/\">how metal domes work<\/a>).<\/p>\n<p>Second, we measured the diameter of plunger\u00a0on front plate, it&#8217;s only 4mm, but the diameter of <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>\u00a0is 6mm, you can see, obviously front plate will\u00a0press the inner function ring <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>.<\/p>\n<div style=\"width: 407px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.metal-domes.com\/blogimages\/2015\/metal-dome-array-force-assembly\/plunger-size.jpg\" alt=\"plunger of front plate\" width=\"397\" height=\"153\" \/><p class=\"wp-caption-text\">plunger of front plate<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Third, we measured the diameter of rubber keypad, it\u2019s 3mm, that\u2019s too large, the larger stress area is, the higher push force will be needed. For 6mm <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>, the recommend size is 1.5mm (25%-30%*diameter of <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>).<\/p>\n<p>Suggestions:<\/p>\n<div style=\"width: 451px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.metal-domes.com\/blogimages\/2015\/metal-dome-array-force-assembly\/suggestion.jpg\" alt=\"metal dome array assembly suggestion\" width=\"441\" height=\"208\" \/><p class=\"wp-caption-text\">metal dome array assembly suggestiong<\/p><\/div>\n<ul>\n<li>Customer need to use front plate to fix the rubber keypad, but this front plate can\u2019t lock <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>, so bottom diameter of front plate should be more than 6mm, then <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>\u00a0will not be fixed by the front plate.<\/li>\n<\/ul>\n<ul>\n<li>Use the suitable plunger to touch and press metal dome, 25%-30% of diameter of <a title=\"metal dome\" href=\"http:\/\/www.metal-domes.com\/products.htm\">metal dome<\/a>.<\/li>\n<\/ul>\n<p>We hope above will be clear for people whom encountered the similar issues.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Recently we received a customer complaint, he said some metal domes arrays couldn&#8217;t work with required (normal) force and need higher push force, and even more some metal domes are locked and no response. The metal domes\u00a0customer uses is S6F-160-D-Ni, &hellip; <a href=\"https:\/\/www.metal-domes.com\/blog\/2015\/03\/24\/why-metal-dome-array-doesnt-work-with-normal-force\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[87,10,100],"tags":[110,21],"class_list":["post-459","post","type-post","status-publish","format-standard","hentry","category-four-leg-metal-dome","category-metal-dome-array","category-metal-dome-assembly-2","tag-metal-dome-array","tag-metal-dome-assembly"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/459","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/comments?post=459"}],"version-history":[{"count":5,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/459\/revisions"}],"predecessor-version":[{"id":466,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/posts\/459\/revisions\/466"}],"wp:attachment":[{"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/media?parent=459"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/categories?post=459"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.metal-domes.com\/blog\/wp-json\/wp\/v2\/tags?post=459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}